IQAir Perfect 16 Installation Manual

Product Data

High-Performance Medical-Grade Residential/Commercial
Air Filtration System

Application
The IQAir Perfect 16 ID Series is a V-bank filter system that connects to the return air duct or supply air duct of a forced air system. This Residential / Commercial Air Filtration System has been designed to provide the highest possible air cleaning rate at the lowest possible pressure drop for residential and commercial forced air systems.Two models are available.The ID-2225 is ideal for airflow rates up to 1200 cfm (2040 m3/h) and the ID-2530 for airflow rates up to 2000 cfm (3400 m3/h).

Features
• Ultra efficient:MERV16 certified (ASHRAE 52.2)
• Low air resistance: 0.22 “w.c. ( 54 Pa) at rated airflow
• Long filter life: 3 years in average home use
• Quick and easy filter replacement: No tools needed
• Easy installation: Requires no electrical connections
• Rugged steel cabinet: Supports weight of furnace
• Medical grade finish: Powder coated galvanized steel
• Fully insulated for installation in unconditioned environments
• Swiss made quality: 10 year warranty

Performance Data:

Residential Installation:

The IQAir Perfect 16 ID-Series can be suspended from exposed ceiling joists or the ceiling surface. Alternatively, it can be floor mounted

1. Choose a location between the main return duct and the furnace, which is readily accessible for checking and replacing the filter. Allow at least 24.5 in. (622 mm) clearance in front of the ID-2225 and 28.5 in. (724 mm) clearance in front of the ID-2530.
2. Adapt connection panel for duct air handler connection as necessary (see page 4). Best performance is achieved with the 16”x 20” opening for the ID-2225 model, and the 20”x 25” opening for the ID-2530. If flex duct is used, it is strongly recommended to use 18” round dove tail collar for the ID-2225 and 20” for the ID-2530 for best performance.
3. Determine the correct air inlet and air outlet side of the system. The air inlet is marked with “Cut this Panel for Duct
Connection – DIRTY AIR IN”. The air outlet is marked with “Cut this Panel for Duct Connection – CLEAN AIR OUT”.
Both panels will need to be cut for the proper fit of the ducting prior to installation.
4. If the Perfect 16 system is to be located immediately alongside the furnace, remove filters and secure cabinet via panel from inside to the furnace with sheet metal screws. Ensure correct airflow direction when reinserting filters.
5. In basement installations, sheet metal turning vanes may be necessary to improve air movement through an elbow in the duct.
6. Use foil tape to seal all duct joints. Note: All leaks on the return side of the system will cause dirty air to leak into the return air stream. Leakage also occurs in many furnaces via the blower door. The blower door should also be sealed with foil tape for the best air cleaning results.
7. Fill out the filter replacement label with the date of the next scheduled filter replacement, which should be no later than 3 years from the current date (based on 50% usage).
8. Check and inspect system for leakage.
9. Test for efficiency with a Particle Scan.

Residential Installation Examples:

Commercial Installation:

Commerciall Installation
The IQAir Perfect 16 ID-Series can be suspended from exposed ceiling joists or the ceiling surface. Alternatively, it can be floormounted.
1. Choose a location between the air handler and the supply registers, which is readily accessible for checking and replacing the filter. Allow at least 24.5 in. (622 mm) clearance in front of the ID-2225 and 28.5 in. (724 mm) clearance in front of the ID-2530.
2. Adapt connection panel for duct air handler connection as necessary (see page 4). Best performance is achieved with the 16”x 20” opening for the ID-2225 model, and the 20”x 25” opening for the ID-2530. If flex duct is used, it is strongly recommended to use 18” round dove tail collar for the ID-2225 and 20” for the ID-2530 for best performance.
3. Determine the correct air inlet and air outlet side of the system. The air inlet is marked with “Cut this Panel for Duct Connection – DIRTY AIR IN”. The air outlet is marked with “Cut this Panel for Duct Connection – CLEAN AIR OUT”.Both panels will need to be cut for the proper fit of the ducting prior to installation.
4. If the Perfect 16 system is to be located immediately alongside the air handler, remove filters and secure cabinet via panel from inside to the furnace with sheet metal screws. Ensure correct airflow direction when reinserting filters.
5. In basement installations, sheet metal turning vanes may be necessary to improve air movement through an elbow in the duct.
6. Use foil tape to seal all duct joints. Note: All leaks on the return side of the system will cause dirty air to leak into the return air stream. Leakage also occurs in many air handlers via the blower door. The blower door should also be sealed with foil tape for the best air cleaning results.
7. Fill out the filter replacement label with the date of the next scheduled filter replacement, which should be no later than 3 years from the current date (based on 50% usage).
8. Check and inspect system for leakage.
9. Test for efficiency with a Particle Scan.

Commercial Installation Examples:

Cutting Openings into Panels:

Cutting Openings into Panels:

Installing the IQAir Perfect 16:

Filter Replacement:

Perfect 16 Warranty & Support

Limited PartsWarranty Conditions
We are proud to cover the IQAir Perfect 16 air cleaning system with a ten (10) year limited warranty. Within 10 years from the original purchase date by the end-user from the authorized IQAir Dealer/Installer if this appliance or any part thereof (with the exception of filters) is proved to be defective by reason only of faulty workmanship or materials, IQAir North America, Inc.will at their option repair or replace the faulty appliance or part free of charge. This warranty is for parts and does not include labor.The warranty for replaced parts will automatically expire with the termination of the original device’s warranty.

This IQAir warranty shall not apply to damage caused by misuse,wear and tear, neglect, unauthorized repair, damage caused by installation, adaptation,modification or use in an improper manner or inconsistent with IQAir’s operating and maintenance instructions, or to wear or deterioration resulting from environmental conditions or to damage sustained during transit. IQAir North America, Inc.will not be liable under this warranty for any fault or damage arising from defective workmanship.

IQAir North America, Inc.will not refund shipping, handling or insurance costs for warranty repairs.Obvious defects must be communicated to the authorized IQAir Dealer/Installer within 10 days of the purchase date.To secure your warranty rights and prevent possible transport damage, all products must be returned in original IQAir packaging. Please keep the original packaging.

Alternatively, original IQAir packaging can be ordered from IQAir North America, Inc.

IMPORTANT NOTE: All products you wish to return for service or repair must be accompanied with a Return
Authorization Number (RA Number).This number can be obtained by contacting the IQAir Technical Support Team. The RA Number must be clearly visible on all external packaging. IQAir North America Inc. reserves the right to refuse any shipment received without RA Number and to return the shipment at the original sender’s cost.

IQAir’s Technical Support Team

Should technical questions arise before, during or after installation, please contact the IQAir / Acevacuums Online Technical Support Team. You may contact the IQAir / Acevacuums Online Technical Support Team at:

Acevacuums Online LLC
300 Fort Evans Rd NE, VA20176
703 997 9292

To expedite your service, please have the following information ready when contacting us:

• IQAir model
• Shell number
• Serial number (found on the base of the unit)
• Your details (name, address, phone, e-mail)
• Date of purchase
• Description of problem

Acevacuums is conveniently located in Loudoun County and Fairfax County to serve customers from Ashburn, Sterling, Leesburg, Great Falls,Herndon, Vienna, Fairfax, Tysons Corner, Falls Church, Annandale, Reston, Chantilly, South Riding and other cities. We sell the best Vacuum cleaners, Air purifiers,  Robotic vacuums,  Central VacuumsCarpet Shampooers, Commercial Vacuums, Floor polishers, Zone heaters and Fans

Fairfax Store : 11110 Lee Hwy, Fairfax : Call 703 997 9292  

Ashburn Store : 44190 Waxpool Rd, Ashburn : Call 703 997 9292

Leesburg Store : 300 Fort Evans Rd NE : Call 703 997 9292

Tags

Related Posts

%d bloggers like this: